Specifications

  • Continuous pure Mica insulation with a very low binding content.
  • Resistive winding with metal strap made of Ni-Cr 80/20 formed by a number control winding machine assuring the utmost uniformity.
  • Steel treated inner sheet suitable for high thermal conductivity.
  • Shiny stainless steel or chromium plated outside sheet.
  • Stainless steel or chromium plated sheet for protective collars in model TA.
  • Power cable with pure nikel copper wires insulated by fiber glassteflon armour and protected by metal braiding.
  • Test certificate.

Models

MTAC

Heating element for extruder heads.

MTNC

Heating elements for plasticization cylinders.

MTAS

Sector heaters with collar draft covering only a part of a cylindrical section.

MTNS

Sector heaters with collar draft covering only a part of a cylindrical section.

MPTC

Flat circular heaters for welders - granulator - parking machines - etc.

MPTA

Plate heaters for filter changers - welding bars - square heads - press - etc.

MPTU

Heating element for U - shaped extruder heads.

MPTL

L-shaped heaters for square head of plastic section bars.

MPTS

Heating elements for square heads.

Know Micaplus

APPLICATIONS

  • On machines for plastics processing with operating temperatures of up to 280°C.

SUGGESTIONS FOR ASSEMBLY 

  • Verify that the inner surface of the heater adheres perfectly to the cylinder.
  • Tighten the screws securely. 
  • Re-tighten the screws securely after 30 minutes of operation to compensate for thermal expansion.

DIMENSIONS 

  • The minimum size available is 50 mm diameter, 20 mm wide band. 
  • Over 470 mm in diameter is appropriate to divide the heater into two or more sectors powered separately. 
  • Below 200 mm diameter, the maximum band width is 500 mm. 
  • Above 200 mm diameter, the maximum band width is 600 mm. 
  • We can make holes or pits, with sizes proportional to the heater as necessary.

ELECTRICALPARAMETERS

  • Maximum specific power 4W/cm2 
  • For lengths of more than 80 mm, links are made via three phase star or triangle and single-phase power doubles.